½Å·Ú¼ºÀåºñ  |  È¯°æ°ü·Ã  |  ÀÌÈ­ÇÐ/°úÇбâ±â  |  ¹°¼ºÃøÁ¤ÀåÄ¡  |  °øÁ¶/±â»ó°ü·Ã  |  ³ó¾÷Çؾç°ü·Ã  |  Àü±â.ÀüÀÚ°èÃø±â    
»óÇ°»ó¼¼°Ë»ö
    °øÁ¶/±â»ó°ü·Ã
     °øÁ¶
¹Ù¶÷°³ºñÇü dz¼Ó°è
¿­¼± dz¼Ó°è
ÃÊÀ½ÆÄ 3Â÷¿ø dz¼Ó°è
dz·® ÃøÁ¤±â
ÈÞ´ë¿ë dz¼Ó°è
     ¿Â/½Àµµ ÃøÁ¤±â
±âÁØ/Ç¥Áؿµµ°è
µðÁöÅÐ ¿Âµµ°è
µðÁöÅÐ ¿Â/½Àµµ°è
¸ð¹ß/¾î°Å½ºÆ®¿Âµµ°è
¾Æ½º¸¸ Åëdz °Ç½À°è
¿­È¯°æ ÃøÁ¤±â
¿Â/½Àµµ µ¥ÀÌŸ·Î°Å
Àڱ⠿½Àµµ ±â·Ï°è

        °øÁ¶ HOME > »óÇ° ¸ÞÀÎ > °øÁ¶/±â»ó°ü·Ã > °øÁ¶   
       

Duck Leakage Tester (´öÆ®´©±â½ÃÇè±â)
Panda PAN-311

Á¦Á¶¿ø :   TSI AIRFLOW(U.K)
°ø±Þ¿ø :   ÇÑÀÏ°úÇÐ

[ Æ¯Â¡ ]
 ▪ Positive¤ýNegative ½ÃÇèÀÌ °¡´ÉÇÕ´Ï´Ù.
 ▪ °í¾Ð(Flow grid)¤ýÀú¾Ð(Nozzle) ½ÃÇèÀÌ °¡´ÉÇÕ´Ï´Ù.
 ▪ EU standard(DW-143) US stadard(SMACNA) ¿¡ ´ëÀÀ°¡´ÉÇÑ ±Ô°ÝÀÔ´Ï´Ù.
 ▪ Å×½ºÆ® ´öÆ® Ç¥¸éÀûÀ» ÀÔ·ÂÇÒ ¼ö ÀÖ½À´Ï´Ù.
 ▪ ´ë±â¾Ð,¿Âµµ,Å×½ºÆ®Á¤¾Ð,dz·®,dz¼Ó,Å×½ºÆ®½Ã°£ ¹× ´©±âÀ² ÀÚµ¿°è»êÀ¸·Î ÇÕ/ºÒ ÆÇÁ¤
   ÀÌ °¡´ÉÇÕ´Ï´Ù.
 ▪ ±¹³» TAB±Ô°ÝÀΠDW143ÀÇ ¸ðµç±Ô°Ý ÀÎÁõ¹Þ¾Ò½À´Ï´Ù. (Duct pressure class A,B,C,D -A,-B,-C,-D)
 ▪ Smoke pellet »ç¿ëÀ¸·Î ´©±âµÇ´Â°÷À» ½Å¼ÓÈ÷ º¸¼ö°¡ °¡´ÉÇÕ´Ï´Ù.
 ▪ ÃøÁ¤µ¥ÀÌŸ ÀúÀå ¹× PCÈ®ÀÎÀÌ °¡´ÉÇÕ´Ï´Ù.
 ▪ ÃøÁ¤µ¥ÀÌŸ¸¦ ºí·çÅõ½ºÇÁ¸°ÅÍ(Option)·Î Áï¼® ÇÁ¸°ÆÃÀÌ °¡´ÉÇÕ´Ï´Ù.
 
[ ÀԷµ¥ÀÌŸ ] 
 ▪ Surface area (´öƮǥ¸éÀûÀÔ·Â)
 ▪ Static pressure (½ÃÇè¾Ð·ÂÀÔ·Â)
 ▪ Flow device (Àú¾Ð&°í¾ÐÀÔ·Â)
 ▪ Tightness class (´©±âµî±ÞÀÔ·Â)
 ▪ Test length (½ÃÇè°¡µ¿½Ã°£ÀÔ·Â)
 ▪ Run test (ÀÛµ¿)

[ Ç¥½Ãµ¥ÀÌŸ ]
 ▪ Leakage factor (´©±âº¯¼ö)
 ▪ Leak limit (´©±â·®)
 ▪ Leak rate (´©±âÀ²)
 ▪ Status (Ok Fail ÆÇÁ¤)
 ▪ Flow device (°í¾Ð/Àú¾Ð)
 ▪ Baro pressure (´ë±â¾Ð)
 ▪ Temperature (´ë±â¿Âµµ)
 ▪ Time (½ÃÇè½Ã°£)
 ▪ Standard (½ÃÇè±Ô°Ý)
 
[ Á¦Ç°±Ô°Ý ] 
 ▪ Wilson radial Flow grid range(°í¾Ð) : 36 ~ 720(CMH)
 ▪ Nozzle adaptor range(Àú¾Ð) : 3.6 ~ 46.9(CMH)
 ▪ Duct pressure : -3735 ~ 3735(Pa)
 ▪ Temperatere : -50 ~ 200(`C)
 ▪ Baro pressure : 690 ~ 1241(hPa)
 ▪ Weight : ¾à 71kg
 ▪ Dimension : 113 x 66 x 51(cm)

[ ÀÎÁõ±Ô°Ý ]
 ▪ BS EN 12237:2003(EU)
 ▪ BS EN 1507:2006(EU)
 ▪ DW/143(EU)
 ▪ Eurovent 2/2(EU)
 ▪ SMACNA HVAC Air Duct leakage Test(US)
¸ð µ¨ ¸í PAN 331
Pressure Measurement (PVM620)
Range ¡¾ 3,735 Pa (¡¾ 15 in. W.G.)
Resolution 0.1 Pa (0.001 in. W.G.)
Accuracy 1% of reading ¡¾ 1 Pa (¡¾ 0.005 in. W.G.)
Actual duct static range ¡¾ 2,500 Pa (¡¾ 10 in. W.G.) at Zero Flow
Volume Measurement (TA465-P)
Wilson radial flow grid High leakage range: 10 to 200 l/s
(36 to 720 m3/hr, 21 to 424 cfm)
15 mm conical inlet Low leakage range: 1 to 13 l/s
nozzle adapter (3.6 to 46.9 m3/hr, 2 to 27.5 cfm)
Resolution 0.01 l/s (0.01 m3/hr, 0.01 cfm)
Accuracy ¡¾ 2.5% of reading ¡¾ 0.01 l/s
(¡¾ 0.04 m3/hr, ¡¾ 0.02 cfm)
Temperature Measurement (TA465-P)
K Type thermocouple probe To EN60584 (IEC 584)
Barometric Pressure Measurement (TA465-P)
Range 690 to 1,241 hPa
(517.5 to 930.87 mm Hg, 20.36 to 36.648 in. Hg)
Accuracy ¡¾ 2% of reading
Power 220 to 240 V, 1 Phase, 50/60 Hz, 10A
Weight 71 kg (157 lbs.)
Dimensions 1,130 mm x 660 mm x 510 mm



»ç¿ëÀÚ Èıâ 0 °Ç
±Û¾´ÀÌ :    ¾ÏÈ£ : Æò°¡
Èıâ :
À̸ÞÀÏ: kyg0900@hanmail.net ¿¬¶ôó: 02-775-7789, FAX: 02-775-7790

ÁÖ¼Ò: ¼­¿ïƯº°½Ã Áß±¸ ´Ùµ¿ 50¹øÁö ÇѼöºôµù 601È£

 ´ëÇ¥  °­ ¿µ ±¸   »ç¾÷ÀÚµî·Ï¹øÈ£ 111-02-01244  Copyright 2008 hanilsc