½Å·Ú¼ºÀåºñ  |  È¯°æ°ü·Ã  |  ÀÌÈ­ÇÐ/°úÇбâ±â  |  ¹°¼ºÃøÁ¤ÀåÄ¡  |  °øÁ¶/±â»ó°ü·Ã  |  ³ó¾÷Çؾç°ü·Ã  |  Àü±â.ÀüÀÚ°èÃø±â    
»óÇ°»ó¼¼°Ë»ö
    È¯°æ°ü·Ã
     ¼öÁú°ü·Ã
PH/ORPÃøÁ¤±â
´ÙÇ׸ñ ¼öÁúÃøÁ¤±â
¿ëÁ¸»ê¼ÒÃøÁ¤±â
ÀÌ¿ÂÃøÁ¤±â
ÀÜ·ù¿°¼ÒÃøÁ¤±â
Àüµµµµ/TDSÃøÁ¤±â
Źµµ°è
CODÃøÁ¤±â
¼öÁúºÐ¼® ŶƮ
MLSS/SSÃøÁ¤±â
BODÃøÁ¤ÀåÄ¡
     ´ë±â/°¡½º
°¡½º °ËÁö±â
°¡¿¬¼º°¡½º ÃøÁ¤±â
³¿»õ ÃøÁ¤±â
µ¶¼º°¡½º ÃøÁ¤±â
¶óµ· ÃøÁ¤±â
¸Þź ÃøÁ¤±â
¹ÝµµÃ¼¿ë °¡½º ÃøÁ¤±â
º¹ÇÕ°¡½º ÃøÁ¤±â
»ê¼ÒÃøÁ¤±â
¿¬¼ÒÈ¿À² ÃøÁ¤±â
¿ÀÁ¸ ÃøÁ¤±â
ÀÏ»êȭź¼ÒCOÃøÁ¤±â
ÀÌ»êȭź¼ÒCO2ÃøÁ¤±â
Æ÷¸§¾Ëµ¥È÷µå ÃøÁ¤±â
CO, CO2 °¡½º ÃøÁ¤±â
VOC ÃøÁ¤±â
¸Å¿¬ÃøÁ¤±â
     ´ë±â/½Ç³» ÀÛ¾÷ȯ°æ
µðÁöÅÐ ºÐÁø°è
Ãʹ̼¼ ÀÔÀÚ °è¼ö±â
°ø±â äÃëÀåÄ¡
¼¼±Õ °è¼ö±â
ûÁ¤µµ ÃøÁ¤±â
À½ÀÌ¿Â ÃøÁ¤±â
¸¶½ºÅ©Âø¿ë±â¹Ð½ÃÇè±â
Á÷°æºÐ¸³Ãæµ¹±â
½Ç³» ÀÛ¾÷ȯ°æ
°ø±âûÁ¤±â
     ¼ÒÀ½/Áøµ¿
¼ÒÀ½ ÃøÁ¤±â
Áøµ¿ ÃøÁ¤±â
ÁöÁø °¨½ÃÀåÄ¡

        È¯°æ°ü·Ã HOME > »óÇ° ¸ÞÀÎ > ȯ°æ°ü·Ã   
       

¿ëÁ¸»ê¼Ò°è(Portable Do meter)/HD2109.1/HD2109.2
HD2109.1/HD2109.2

Á¦Á¶¿ø :   DELTA OHM
°ø±Þ¿ø :   ÇÑÀÏ°úÇÐ

 

¡Ü ´ëÇüÈ­¸éÀÇ ¾×Á¤À» äÅà ¼öÄ¡ È®ÀÎÀÌ ½±½À´Ï´Ù.
¡Ü RS-232C Æ÷Æ®¸¦ ³»ÀåÇÏ°í ÀÖ¾î ½Ç½Ã°£À¸·Î µ¥ÀÌÅ͸¦ PC³ª ÇÁ¸°ÅÍ·Î Àü¼ÛÀÌ °¡´ÉÇÕ´Ï´Ù.
¡Ü ÃÖ´ë.ÃÖ¼Ò.Æò±Õ.HOLD.REL.ÀÚµ¿off ±â´ÉÀÌ ÀÖ¾î »ç¿ëÀÚÀÇ Æí¸®¼ºÀ» Çâ»óµË´Ï´Ù.
¡Ü IP67ÀÇ ¹æ¼ö µî±ÞÀÔ´Ï´Ù.
¡Ü HD2109.2 µ¥ÀÌÅÍ ÀúÀåÀ» °¡Áö°í ÀÖ½À´Ï´Ù.(18000°³)
¡Ü ´Ù¾çÇÑ ¼¾¼­¸¦ Áö¿øÇÕ´Ï´Ù.
¡Ü 2Á¡ ¶Ç´Â 3Á¡ ±³Á¤ÇÕ´Ï´Ù.

 

  ±Ô°Ý
MODEL
HD2109.1
HD2109.2
ÃøÁ¤Ç׸ñ¹ü À§
»ê¼Ò³óµµ
0.00 ~ 90.00§·/§¤
»ê¼ÒÁö¼ö
0.0 ~ 600.0 %
¿Â µµ
0 ~ 45¡É(Pt 100 measurement range -200~+650¡É)
´ë±â¾Ð
0.0 ~ 1100.0 mbar
Á¤È®µµ
»ê¼Ò³óµµ
¡¾0.03§·/§¤
»ê¼ÒÁö¼ö
¡¾0.3%
¿Â µµ
¡¾0.25¡É
´ë±â¾Ð
¡¾2mbar
Data Logger
-
18000°³
¸Þ¸ð¸®°£°Ý¼³Á¤
-
1~3600ÃÊ(1½Ã°£)
Ãâ ·Â
RS-232C
Interface
-
USB Interface
µð½ºÇ÷¹À̱԰Ý
2 ¡¿ 4¨ö digit 52 ¡¿ 42mm
185L ¡¿ 90W ¡¿ 40Hmm / 470g(°ÇÀüÁö Æ÷ÇÔ)
¼Ò Àç
ABS, °í¹«
ÀüÁö¼ö¸í
¾ËÄ«¶óÀÎ ¹èÅ͸®·Î 200½Ã°£ »ç¿ë.
»ç¿ëÀü¿ø
DC 9V/250mA


¡ØÁÖ¹®CODE
HD2109.1KE: The kit is composed of: instrument HD2109.1,calibrator DO9709/20, connection cable for serial output HD2110CSNM, 4 1.5V alkaline batteries, operation manual, case and DeltaLog9 software. The dissolved Oxygen and temperature probes must be ordered sepa-rately.
HD2109.2K: The kit is composed of: instrument HD2109.2, datalogger, calibrator DO9709/20, connection cable for serial output HD2101/USB, 4 1.5V alkaline batteries, operation manual, case and DeltaLog9 software. The dissolved Oxygen and temperature probes must be ordered separately.
HD2110CSNM: 8-pole connection cable MinDin-Sub D 9-pole female for BS232C. HD2101/USB: Connection cable USB2.0 connector type A-8-pole MiniDin(not suitable for HD2109.1K)
DeltaLog9: Software for download and management of the data on PC using Widows 98 to XP operating systems.
AF209.60: Stabilized power supply at 230Vac/9Vdc-300mA mains voltage.
S'print-BT: On request, portable, serial input, 24 column thermal printer, 58mm paper width.
DO9700: zero solution
DO9701: electrolyte solution.
¡ØOption £ªSICRAM¸ðµâ ºÎÂø Pt100
MODEL
Type
ÃøÁ¤¹üÀ§
Á¤µµ
TP87 Immersion -50¡É~ +200¡É ¡¾0.25¡É (-50¡É~+200¡É)
TP4721 Immersion -196¡É~ +500¡É ¡¾0.25¡É (-196¡É~+350¡É) ¡¾0.4¡É (+350¡É~+500¡É)
TP4721.0 Immersion -50¡É~ +400¡É ¡¾0.25¡É (-50¡É~+350¡É) ¡¾0.4¡É (+350¡É~+400¡É)
TP473P.0 Penetration -50¡É~ +400¡É ¡¾0.25¡É (-50¡É~+350¡É) ¡¾0.4¡É (+350¡É~+400¡É)
TP474C.0 Contact -50¡É~ +400¡É ¡¾0.3¡É (-50¡É~+350¡É) ¡¾0.4¡É (+350¡É~+400¡É)
TP4721.5 Immersion -50¡É~ +400¡É ¡¾0.3¡É (-50¡É~+350¡É) ¡¾0.4¡É (+350¡É~+400¡É)
TP4721.10 Immersion -50¡É~ +400¡É ¡¾0.3¡É (-50¡É~+350¡É) ¡¾0.4¡É (+350¡É~+400¡É)
¡ØDirect 4wire Pt100 Probes
Model
Type
ÃøÁ¤¹üÀ§
Á¤µµ
TP47.100
4wrie Pt100
-50¡É~+400¡É
Class A
Common characteristics
Resolution 0.1¡É
Temperature drift @20¡É 0.003%/¡É

Combined dissolved Oxygen/temperature probes
DO9709SS: The kit includes: combined probe for measurement of O2 and temperature with replaceable membrane, three membranes, 50ml of zero solution, 50ml of electrolyte solution. Cable length 2m.¨ª12mm¡¿120mm.
DO9709SS.5: The kit includes: combined probe for measurement of O2 and temperature, replaceable membrane, ¨ª12mm¡¿120mm. Cable length 5m, three membranes, 50ml of zero solution, 50ml of electrolyte solution.
DO9709SS.10: The kit includes: combined probe for measurement of O2 and temperature, replaceable membrane, ¨ª12mm¡¿120mm. Cable length 10m, three membranes, 50ml of zero solution, 50ml of electrolyte solution.

 

»ç¿ëÀÚ Èıâ 0 °Ç
±Û¾´ÀÌ :    ¾ÏÈ£ : Æò°¡
Èıâ :
À̸ÞÀÏ: kyg0900@hanmail.net ¿¬¶ôó: 02-775-7789, FAX: 02-775-7790

ÁÖ¼Ò: ¼­¿ïƯº°½Ã Áß±¸ ´Ùµ¿ 50¹øÁö ÇѼöºôµù 601È£

 ´ëÇ¥  °­ ¿µ ±¸   »ç¾÷ÀÚµî·Ï¹øÈ£ 111-02-01244  Copyright 2008 hanilsc